Appendix B
11
Appendix B
ODORATOR Correction Chart for Propane
This chart assumes the ODORATOR has been properly zeroed and allowed
to run for at least one minute.
ODORATOR %
Gas Reading
Actual % L.E.L. Actual % Gas
.00 0.0 0.00
.05 2.4 0.05
.10 3.9 0.09
.15 5.5 0.12
.20 7.5 0.17
.25 9.0 0.20
.30 10.5 0.23
.35 12.5 0.28
.40 15.0 0.33
.45 18.0 0.40
.50 21.0 0.45
.55 Ref. 25.0 Ref. 0.55 Ref.
.60 30.0 0.66
.65 35.0 0.77
.70 40.0 0.88
.75 46.0 1.01
.80 52.0 1.14
Propane Correction Chart, .55% Reference