Vista de pagina 22
(Figure 10)
As you can see from Figure 10, in preliminary detection the Direct Contact
Microphone is connected with the Amplier Module and the Headset is
plugged into the jack on the Amplier Module. The Volume is then turned
clockwise and the amplication is turned up enough so that the sound
of a leak is recognizable. The position of 4 to 6 on the volume control is
recommended for best sound intensity.
Procedure of Preliminary Detection: The point of the Direct Contact
Microphone is placed on the part of the line, which is to be checked. The
point should be abraded and rmly held against the line to insure good
contact. When the Direct Contact Microphone is rmly placed on the line,
the “Listencontrol switch on the Amplier Module is depressed. This will
complete the electrical contact between the microphone and the amplier.
The switch should not be depressed before or while making contact, as
the noise of making contact is unpleasant to the ear. Tests are made in this
manner and sound levels for the tests compared (see Figure 11). Figure
12 is an example of the above technique in a eld situation. The Direct
Contact Microphone should not be immersed in water. If a test must be
taken in deep water, use the extensions or contact the line or desired test
point with a rod or key. The tip of the Direct Contact Microphone is then
used on the rod or key.
20
Vista de pagina 22
1 2 ... 18 19 20 21 22 23 24 25 26 27 28 ... 38 39

Comentarios a estos manuales

Sin comentarios