Hi Flow
Sampler Introduction
6 Instruction 0055-9017
The main unit consists of an intrinsically safe, high-flow blower that pulls air from
around the component being tested through a flexible hose and into a gas manifold
located inside the unit. The sample is first passed through a venturi restrictor where the
measured pressure differential is used to calculate the sample’s actual flow rate. Next, a
portion of the sample is drawn from the manifold and directed to a combustibles sensor
that measures the sample’s CH
4
concentration in the range of 0.05 to 100% gas by
volume. A second identical combustibles sensor channel measures the background CH
4
level within the vicinity of the leaking component. The final element in the sampling
system is a blower that exhausts the gas sample back into the atmosphere away from
the sampling area.
The measured flow rate and the measured CH
4
levels (both leak and background levels)
are used to calculate the leak rate of the component being tested, with all measured
and calculated values being displayed on the hand-held control unit.
1.2 Material Supplied
High Flow Sampler Unit
Backpack
6 Foot, 1.5 Inch Hose Assembly
Battery Pack (Qty. 2)
Battery Charger w/ Power Supply
Control Unit with LCD and 4-button keypad
Assortment of Attachments (for complete capture of the gas leak)
Flange Strap 34", 80", and 137"
Capture Bag 36" x 36"
Beveled Nozzle 6.5" and 24"
Bag Nozzle
Bellows Tool
Claw Tool
1.3 Why Use the Hi Flow
Sampler?
Allows ranking of gas leaks in leak-rate order
Allows users to determine if the potential savings in lost gas by repairing a leak
Allows users to determine payback periods for particularly expensive repairs
Allows more cost-effective use of your maintenance budget
Identifies problem areas
Determines baseline leakage conditions
EPA Best Management Practice Tool for Directed Inspection and Maintenance
Programs at Natural Gas Facilities
Provides permanent record of leakage and repair
Approved Measurement tool in conjunction with United Nations Framework
Convention on Climate Change Methodology 0023, Leak Reduction at Natural Gas
Facilities
Pays for itself in recovered gas